The Battery Simulator (BS) consists of a power supply as a load independent voltage source. To simulate the characteristic curve of a battery, the power supply can be adjusted while running the test program. The battery type, the battery capacity and the battery condition (age, temperature) can be simulated as well due to the adjustability of the resistance. Like real batteries with different open circuit voltages the BS can also adjust the open circuit voltage.
A 32 Bit digital signal processor ensures high speed control and data aquisition. A variety of options are available such as additional input channels, CAN-Bus interface and the RS232 interface to temperature chamber.
The simplified theoretical model of a battery is used to adjust DC output voltage of the Battery Simulator.
The test system consisting of battery simulator BS and the software BTS 600 can replace real batteries in numerous applications. Typical applications are test bench lines for combustion engines and electric drive systems.
Control interface: |
MBT |
PC software: |
BTS-600 |
External control: |
Analogue Input, CAN-Bus, RS-232 |
Resolution: |
± 15 Bit |
Data Acquisition Rate: |
10 ms |
Accuracy: |
± 0.25% Full Scale |
DC current ripple: |
≤ 1% Full Scale |
Current rise time (10-90% load) I: |
< 5 ms |
Current rise time (10-90% load) U: |
< 20 ms |
Input power supply: |
3-phase, 50/60 Hz |
Ambient temperature: |
10-40 °C (50-104 °F) |
Model Designation |
Imax [A] |
UImax [V] |
Umax [V] |
Cabinet Size |
BS 150-500/40 kW |
150 |
265 |
500 |
I 1 |
BS 220-500/40 kW |
220 |
180 |
500 |
I 1 |
BS 330-500/40 kW |
330 |
120 |
500 |
I 1 |
BS 150-500/60 kW |
150 |
400 |
500 |
I 1 |
BS 220-500/60 kW |
220 |
270 |
500 |
I 1 |
BS 330-500/60 kW |
330 |
180 |
500 |
I 1 |
BS 300-500/80 kW |
300 |
265 |
500 |
I 2 |
BS 450-500/80 kW |
450 |
175 |
500 |
I 3 |
BS 600-500/80 kW |
600 |
130 |
500 |
I 3 |
BS 300-500/120 kW |
300 |
400 |
500 |
I 3 |
BS 450-500/120 kW |
450 |
265 |
500 |
I 3 |
BS 300-500/160 kW |
300 |
530 |
500 |
I 4 |
BS 450-500/160 kW |
450 |
355 |
500 |
I 4 |
BS 600-800/240 kW |
600 |
400 |
800 |
I 5 |
BS 600-800/480 kW |
600 |
800 |
800 |
I 6 |
Other current and voltage ranges available on request.
Size |
Dimensions (HxWxD) [mm] |
I 1 |
2200 x 800 x 800 (86.7'' x 31.5'' x 31.5'') |
I 2 |
2200 x 1000 x 1000 (86.7'' x 39.4'' x 39.4'') |
I 3 |
220 x 1600 x 800 (86.7'' x 63'' x 31.5'') |
I 4 |
2200 x 2000 x 1000 (86.7'' x 78.8'' x 39.4'') |
I 5 |
2200 x 3000 x 800 (86.7'' x 118.2'' x 31.5'') |
I 6 |
2200 x 6000 x 1200 (86.7'' x 236.3'' x 47.5'') |
- Additional Voltage, Temperature, Analog Inputs
- I/O for Auxiliary Devices, RS-232, CAN Interface
- Paralleling of Units
|