The Universal Battery Tester (UBT) is particularly designed for cycle life and capacity testing of automotive batteries. It can also be used for testing other types of batteries. The UBT performs charging and discharging in accordance with the programmed test schedule. Parameters are constant current, constant voltage, constant resistance and constant power.
For data evaluation, the UBT runs either with Digatron/Firing Circuits well-known Battery Manager or BTS-600 software. Battery Manager is usually applied for quality assurance and high volume testing, whereas BTS-600 is used for research and development requirements.
In the standard version, one cabinet contains 5 or 10 charge-/discharge circuits connected to one common DC bus bar power supply.
Numerous options are available such as paralleling circuits, single cell operation, cell/battery drop out , multi range switching, temperature inputs, inputs for reference electrodes, data-logger interface, CAN-Bus interface as well as digital inputs and outputs and a RS 232 interface to the climatic chamber.
Standardized test schedules (EN, DIN, SAE, IEC,JS etc.) and/or userdefined test schedules for automotive batteries and all other types of batteries. The modular power module design, the combination of a variety of options and the flexible program editor allow setting up an automated IEC test stand effecting long term cycle life and cold cranking tests without any manual battery handling.
Control Interface: |
BTS |
PC Software: |
Battery Manager or BTS-600 |
Accuracy: |
±0.05 % Full Scale |
Resolution |
±15 Bit |
Data Acquisition Rate: |
100 ms |
Rise Time |
< 10 ms |
Fast Mode Switching: |
< 50 ms |
Input Power Supply: |
3-phase, 50/60 Hz |
Ambient Temperature: |
10-40°C (50-104°F) |
Model Designation |
Current per Circuit [A] |
Voltage Charge [V] |
Voltage Discharge [V] |
Number of Circuits |
Cabinet Size |
Power Supply [kVA] |
UBT 30-18-5 |
0.03 - 30 |
5 - 18 |
15 - 5 |
5 |
S |
4 |
UBT 30-18-10 |
0.03 - 30 |
5 - 18 |
15 - 5 |
10 |
S |
8 |
UBT 50-18-5 |
0.05 - 50 |
10 - 18 |
15 - 5 |
5 |
S |
8,1 |
UBT 50-18-10 |
0.05 - 50 |
10 - 18 |
15 - 5 |
10 |
M |
16,2 |
UBT 100-18-5 |
0.1 - 100 |
10 - 18 |
15 - 5 |
5 |
M |
15 |
UBT 100-18-10 |
0.1 - 100 |
10 - 18 |
15 - 5 |
10 |
L |
30 |
UBT 150-18-5 |
0.15 - 150 |
10 - 18 |
15 - 5 |
5 |
M |
23 |
UBT 30-60-5 |
0.03 - 30 |
10 - 60 |
60 - 5 |
5 |
M |
12,5 |
UBT 50-60-5 |
0.05 - 50 |
10 - 60 |
60 - 5 |
5 |
M |
20 |
UBT 100-60-3 |
0.1 - 100 |
10 - 60 |
60 - 5 |
3 |
M |
24 |
Other current and voltage ranges available on request.
Size |
Dimensions (H x W x D) [mm] |
Output max. DC Current [A] |
S |
1100 x 670 x 850 ( 43.3" x 26.4" x 33.5") |
600 |
M |
1950 x 670 x 850 ( 76.8" x 26.4" x 33.5") |
1200 |
L |
2250 x 670 x 850 ( 88.6" x 26.4" x 33.5") |
1200 |
- Paralleling Circuits
- High Speed Data Acquisition and Control
- Single Cell Operation
- Additional Voltage, Temperature, Analog Inputs
- Inputs for Reference Electrodes
- I/O for Auxiliary Devices
- RS-232, CAN Interface
|